UPS (uninterruptible power supply)
A UPS (uninterruptible power supply) is a device that provides temporary power to equipment when the mains voltage fails or deviates. It protects servers, computers and network infrastructure from failures, data loss and damage during power surges and outages.
A UPS (uninterruptible power supply, UPS) is a device that provides temporary power to equipment when the mains voltage fails or deviates. When the electricity goes out, it instantly switches the load to built-in batteries, allowing work to be completed correctly and data to be saved, and smooths out voltage surges and interference, protecting equipment from damage.
What is a UPS
An uninterruptible power supply (UPS) is a hardware device between the network and equipment. Its main functions: backup power — when voltage disappears, the UPS switches to batteries in milliseconds; stabilization — normalizes voltage dips and surges; filtering — suppresses impulse interference and high-frequency noise; management — gives a signal for correct system shutdown. UPS units are necessary for servers, storage systems, switches, routers, medical and banking systems, as well as workstations where data loss is critical. Without a UPS, a power failure can cause damage to unsaved data, disk corruption and a sudden stop of business processes.
Types of UPS
By operating technology, three main types are distinguished. Standby (Offline/Standby) — the simplest and cheapest: they switch to batteries only when the mains fails and do not smooth out voltage deviations; suitable for home appliances and peripherals. Line-interactive (Line-Interactive) — equipped with a stabilizer, correct voltage fluctuations and switch to batteries on a complete outage; optimal for office computers, file servers and network equipment. Double conversion (Online/On-Line) — the load is constantly powered from the inverter through batteries, so there is no switching and the voltage is always perfectly stable; used for critical servers, storage systems and data centers.
How to choose a UPS
When choosing, the total equipment capacity is calculated (VA or W) and 20–30% of headroom is added. The required battery runtime is determined: 5–15 minutes is usually enough for a correct shutdown, for longer system support — additional batteries or a diesel generator. The UPS type (Offline for peripherals, Line-Interactive for servers, Online for data centers), hot-swappable batteries, network management (SNMP) and monitoring are taken into account. For server rooms, UPS units are connected to a common power system with a generator and an automatic transfer switch.
UPS maintenance
UPS batteries wear out after 3–5 years, so their resource is monitored by built-in diagnostics and replaced when capacity drops. A scheduled battery test is recommended once a quarter to make sure the switching is correct. The room with a UPS should be clean, dust-free and at normal temperature: overheating accelerates battery degradation. For data centers, N+1 redundancy and SNMP monitoring are used.
Frequently asked questions
What is a UPS and why is it needed?
A UPS is a device that provides uninterrupted power to equipment during power grid failures. It protects servers and computers from data loss during power outages and from damage during voltage surges and interference.
What types of UPS exist?
Standby (Offline) — switch to batteries when the mains fails; line-interactive (Line-Interactive) — additionally stabilize voltage; double conversion (Online) — the load is constantly powered through the inverter, ideal for servers and data centers.
How to calculate UPS power?
Sum up the power consumption of the equipment in watts and add 20–30% of reserve. For example, for a server with an 800 W power supply, a UPS of 1000–1200 VA is suitable. Power is specified in volt-amperes (VA) or watts (W) — compare the model with the required load.
How long should a UPS run on batteries?
5–15 minutes of autonomy is enough for a correct system shutdown. For longer operation support, external batteries are added or a diesel generator is connected, which takes over the load after the UPS stops.
How is an Online UPS better than a Line-Interactive one?
An Online UPS constantly powers the load from the inverter through batteries, so the voltage is always stable and there is no switching. A Line-Interactive UPS corrects deviations with a stabilizer, but briefly switches to batteries during a complete outage. For critical servers and storage systems, Online is chosen.
Do I need a UPS for a home computer?
Yes — a UPS will protect the PC from loss of unsaved data and damage during an outage or voltage surge. For home and office, a 600–1000 VA line-interactive UPS is enough for a correct shutdown.
What is UPS hot battery swap?
This is a function that allows replacing batteries without disconnecting the UPS and the load. It allows maintaining an uninterruptible power supply in the server room without interrupting the operation of critical equipment and is available in models with removable battery modules.
How is a UPS different from a generator installation?
A UPS provides instant battery backup operation (seconds to minutes) but has a limited capacity. A generator provides long-term power but takes several minutes to start and spin up. In server rooms they are used together: the UPS supports the load while the diesel generator starts.
Other terms in «Infrastructure»